Battery Analyzer

Battery Analyzer

8-Channel Battery Analyzer with Laptop & Software

1]Battery Analyzer 5 V, 1 mA

Description:
This is an eight-channel battery analyzer to analyze small coin cells and cylindrical batteries from 0.002 mA to 1 mA, up to 5V. Each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software.

Specifications:

Supply Voltage 220 V AC
Power Consumption 30 W
Current Range: 0.002 mA – 1 mA
Accuracy: ±(0.05% of reading + 0.1% of range)
Voltage Range: 0.5 – 5 V Programmable
Accuracy: ±(0.05% of reading + 0.1% of range)
Data Register Conditions Time interval: 1 – 900 s
Max. measurement cycles 9999 cycles
Channels Eight independent programmable channels
Each channel can set different working modes and functions independently
Program & Software The software (TC5.3) with calibration function is included to set various working modes for measuring capacity and life cycle for all types of rechargeable batteries.
Working modes Include constant current discharge, constant current charge, constant voltage charge, rest, etc.
Limited threshold conditions include voltage, current, time, capability, negative voltage slope, etc.
With real-time monitoring windows and integrated graph/data windows, the testing process can be observed more directly and efficiently.
During the test, the software will provide instructions and warnings for assistance.
The calibration software can be used to calibrate the analyzer.
MS Excel is pre-installed for you to output the Excel data file.

2] Battery Analyzer 5 V, 5 mA

Description:
This is an eight-channel battery analyzer to analyze small coin cells and cylindrical batteries from 0.02 mA to 5 mA, up to 5V. Each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software.

Specifications:

Supply Voltage AC 220 V ± 10% / 50Hz
Resolution AD: 15 bit; DA: 12 bit
Input Resistance ≥ 1MΩ
Input Power 747 mW
Voltage Charging range: 10 mV ~ 5 V
Discharging range: 10 mV ~ 5 V
Accuracy: ± 0.1% of range(Full-scale)
Stability: 0.1%
Current Charging range: 0.02 mA ~ 5 mA
Discharging range: 0.02 mA ~ 5 mA
Accuracy: ± 0.1% of range(Full-scale)
Stability: 0.1%
Power Output power per channel: 50 mW
Stability: 0.2 %
Time Current response Time: 20ms
Channels Eight independent programmable channels.
Each channel can set different working modes and functions independently.
Program & Software The software (TC5.3) with calibration function is included to set various working modes for measuring capacity and life cycle for all types of rechargeable batteries.
Working modes Include constant current discharge, constant current charge, constant voltage charge, rest, etc.
Limited threshold conditions include voltage, current, time, capability, negative voltage slope, etc.
With real-time monitoring windows and integrated graph/data windows, the testing process can be observed more directly and efficiently.
During the test, the software will provide instructions and warnings for assistance
The calibration software can be used to calibrate the analyzer.
MS Excel is pre-installed for you to output the Excel data file.

3] Battery Analyzer 5 V, 10 mA

Description:
This is an eight-channel battery analyzer to analyze small coin cells and cylindrical batteries from 0.1 mA to 10 mA, up to 5V. Each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software. This system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, and battery pack testing, etc.

Specifications:

Supply Voltage 220 V AC, 50 Hz Single phase
Power Consumption 30 W
Current Range: 0.1 mA- 10 mA
Accuracy: ±(0.05% of reading + 0.1% of range)
Data register conditions Time interval: 1 – 900s
Max. measurement cycles 9999 cycles
Channels Eight independent programmable channels
Each channel can set different working modes and functions independently
Program & Software The software (TC5.3) with calibration function is included to set various working modes for measuring capacity and life cycle for all types of rechargeable batteries.
Working modes Include constant current discharge, constant current charge, constant voltage charge, rest, etc.
Limited threshold conditions include voltage, current, time, capability, negative voltage slope, etc.
With real-time monitoring windows and integrated graph/data windows, the testing process can be observed more directly and efficiently.
During the test, the software will provide instructions and warnings for assistance.
The calibration software can be used to calibrate the analyzer.
MS Excel is pre-installed for you to output the Excel data file.

4] Battery Analyzer 5 V, 3 A

Description:
This is an eight-channel battery analyzer to analyze small coin cells and cylindrical batteries from ±3A, up to 5V. Each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software.

Specifications:

Supply Voltage AC 220 V ± 10 %, 50 Hz
Current Output Range ± 3A
Voltage Measurement Range Charging Range: 0 ~ 5 V
Discharging Range: 2.5 ~ 5 V
Input Resistance ≥ 1MΩ
Power 120 W
Current Measurement Accuracy ±(0.05% of reading + 0.1% of range)
Voltage Measurement Accuracy ±(0.05% of reading + 0.1% of range)
Time Resolution 1 s
Step Time Range (1s ~ 65535m) / step
Channels Eight independent programmable channels·
Each channel can set different working modes and functions independently
Program & Software The software (TC5.3) with calibration function is included to set various working modes for measuring capacity and life cycle for all types of rechargeable batteries.
Working modes Include constant current discharge, constant current charge, constant voltage charge, rest, etc.
Limited threshold conditions include voltage, current, time, capability, negative voltage slope, etc.
With real-time monitoring windows and integrated graph/data windows, the testing process can be observed more directly and efficiently.
During the test, the software will provide instructions and warnings for assistance.
The calibration software can be used to calibrate the analyzer.
MS Excel is pre-installed for you to output the Excel data file.